ICS 03.120.30A 41中华人民共和国国家标准GB/T 6379.1-2004/ISO 5725-1:1994部分代替GB/T 6379-1986GB/T 11792-1989测量方法与结果的准确度(正确度与精密度)第1部分:总则与定义Accuracy (trueness and precision)of measurement methods and results-Part 1 :General principles and definitions(ISO 5725-1:1994,IDT)2004-06-02发布2005-01-01实施中华人民共和国国家质量监督检验检疫总局中国国家标准化管理委员会发布www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:1994目次前言······················,·,,,···。·································,···············,,··················,,,·,·········……m引言······,··································································································,····,··……N1范围··,······························································································,············……12规范性引用文件··························,·····················································,·············……13定义··············,,,,,,,,·········,·················,,,,,,,············,,,,,·。。。·······,,,,··········……I4准确度试验定义的实际含义········,····················,··································一““““·‘……44. 1标准测量方法··,······················,······························,·····································……44.2准确度试验,·····························」·····,····························································……54.3同一测试对象·········1·····4·····,,·.................·························,,····‘····,…54.4短暂的时间间隔................................................................................................... 54. 5参与的实验室·············································,·························,························……54.6观测条件································,·····································································……55统计模型·············,,························································,··················,············……65. 1基本模型········,,,················································································,··········……65. 2基本模型和精密度的关系·················……,’····························,···············,·······,·……75. 3其他可供选择的模型··················································,····································一76为估计准确度试验设计方面的考虑·························‘································,·······……““76. 1准确度试验的计划······,,,·,,,,,·‘··,···········,,,··,············,,,,,,·······.......... 76. 2标准测量方法························,··,··············,,········································,··········……76. 3准确度试验的实验室的选择···········································,····················……’‘’“““““‘86.4用于准确度试验物料的选择·...............................·········································……‘二107准确度数据的应用,,,··········································································,·············……H7. 1正确度和精密度数值的发布················,·,·····,,,,,·································……“““““‘二‘117.2正确度和精密度数值的实际应用····,·············,··,·······················,·,··········……‘··……‘””12附录A(规范性附录)GB/T 6379所用的符号与缩略语·············································……13附录B(规范性附录)精密度度量不确定度的图示····,·················································……15附录C(资料性附录)参考文献····,·,,··,·········,·,,,,,,,,·····、··‘···,,,··································一16www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:1994月U舀GB/T 6379((测量方法与结果的准确度(正确度与精密度)》分为六部分.其预期结构及对应的国际标准为:—第1部分:总则与定义(ISO 5725-1:1994,IDT)—第2部分:确定标准测量方法的重复性和再现性的基本方法((ISO 5725-2,1994,IDT)—第3部分:标准测量方法精密度的中间度量(对应ISO 5725-3;1994)—第4部分:确定标准测量方法正确度的基本方法(对应ISO 5725-4;1994)—第5部分:确定标准测量方法精密度的可替代方法(对应ISO 5725-5;1998)—第6部分:准确度值的实际应用(对应ISO 5725-6:1994)本部分为GB/T 6379的第1部分。GB/T 6379的本部分等同采用国际标准ISO 5725-1:1994((测量方法与结果的准确度(正确度与精确度)—第1部分:总则与定义》及ISO于1998-02-15发布的对1994版ISO 5725-1的技术修改单。GB/T 6379第1部分至第6部分作为一个整体代替GB/T 6379-1986和GB/T 11792-19890标准中将原精密度概念加以扩展,增加了正确度概念,统称为准确度;除重复性条件和再现性条件外,增加了中间精密度条件。本部分的附录A和附录B为规范性附录,附录C为资料性附录。本部分由中国标准化研究院提出。本部分由全国统计方法应用标准化技术委员会归口。本部分起草单位:中国标准化研究院、中国科学院数学与系统科学研究院、辽宁出人境检验检疫局、广州出人境检验检疫局。本部分主要起草人:于振凡、冯士雍、刘文、姜健、丁文兴、王斗文、肖惠、李成明本部分于2004年首次发布。www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:1994引言0. 1 GB/T 6379用两个术语“正确度”与“精密度”来描述一种测量方法的准确度正确度指大量测试结果的(算术)平均值与真值或接受参照值之间的一致程度;而精密度指测试结果之间的一致程度。0.2考虑精密度的原因主要是因为假定在相同的条件下对同一或认为是同一的物料进行测试,一般不会得到相同的结果。这主要是因为在每个测量程序中不可避免的会出现随机误差,而那些影响测量结果的因素并不能完全被控制在对测量数据进行实际解释过程中,必须考虑这种变异。例如,测试结果与规定值之间的差可能在不可避免的随机误差范围内,在此情形,测试值与规定值之间的真实偏差是不能确定的。类似的,当比较两批物料的测试结果时,如果它们之间的差异是来自测量程序中的内在变化,则不能表示这两批物料的本质差别0. 3很多不同的因素(除假定相同的样品之间的差异外)都能够引起测量方法的结果变异,它们包括:a)操作员;b)使用的设备;c)设备的校准;d)环境(温度、湿度、空气污染等);e)不同测量的时间间隔。由不同操作员所做的测量和在不同设备上进行的测量通常要比在短时间内由同一个操作员使用相同的设备进行测量产生的变异大。0.4描述重复测量结果之间的变异的一般术语是精密度。精密度的两个条件,即重复性和再现性条件对很多实际情形是必需的,对描述测量方法的变异是有用的。在重复性条件下,上面所列的因素a)到e)皆保持不变,不产生变异;而在再现性条件下,它们是变化的,能引起测试结果的变异。因此重复性和再现性是精密度的两个极端情况:重复性描述变异最小情况,而再现性则描述变异最大情形。当因素a)到e)的一个或多个允许变化时,位于精密度的上述两个条件的其他中间条件也是可以想象的,它们可用于某些特定的环境。精密度通常用标准差表示0.5当已知或可以推测所测量特性的真值时,测量方法的正确度即为人们所关注。尽管对某些测量方法,真值可能不会确切知道,但有可能知道所测量特性的一个接受参照值。例如,可以使用适宜的标准物料或者通过参考另一种测量方法或准备一个已知的样本来确定该接受参照值。通过把接受参照值与测量方法给出的结果水平进行比较就可以对测量方法的正确度进行评定。正确度通常用偏倚来表示例如,在化学分析中,如果所用的测量方法不能测出某种元素的全部,或者由于一种元素的存在而干扰了另一种元素的确定,就会产生偏倚。0.6 ISO 5725中使用的一般术语“准确度”,既包含正确度也包含精密度。“准确度”这一术语在过去一段时间只用来表示现在称为正确度的部分。但是对很多人来说,它不仅包括测试结果对参照(标准)值的系统影响,也应包括随机的影响。很长时间以来,术语“偏倚”一直被限制用于统计问题,由于它在某些领域中(如医学界和法律界)曾经引起过哲学上的异议,因此引进术语“正确度”似更强调其正面含义。www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:1994测量方法与结果的准确度(正确度与精确度)第1部分:总则与定义范围1. 1 GB/T 6379系列标准的目的如下:a)阐述评定测量方法与结果的准确度(正确度与精密度)的一般原理与应用,通过试验对不同测量进行实际的估计(GB/T 6379. 1);b)通过试验提供估计测量方法精密度的两个极端度量的基本的方法(GB/T 6379. 2);c)提供为获得精密度中间度量的程序,给出其适用的环境和估计方法((ISO 5725-3) ;d)提供为确定测量方法正确度的基本方法((ISO 5725-4);e)为某些特定的应用条件,提供有别于GB/T 6379. 2和ISO 5725- 4中基本方法的确定测量方法的正确度与精密度的其他可替代的方法((ISO 5725-5);幻提供正确度和精密度上述度量的一些实际应用1. 2 GB/T 6379的本部分所涉及的测量方法,特指对连续量进行测量,并且每次只取一个测量值作为测试结果的测量方法,尽管这个值可能是一组观测值的计算结果GB/T 6379的本部分定量定义了一种测量方法给出正确结果的能力(正确度)与重复同样结果的能力(精密度)。这就意味着可用完全相同的方法来测量完全相同的事物,且测量过程是受控的。GB/T 6379的本部分适用于多种范围的物料(物质或材料),包括液体、粉状物和固体物料,这些物料可以是人工制造的,也可以是自然存在的,只要对物料的异质性进行适当考虑。2规范性引用文件下列文件中的条款通过GB/T 6379的本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版本均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件其最新版本适用于本部分。GB/T 3358.1-1993统计学术语第一部分:一般统计术语GB/T 3358. 2-1993统计学术语第二部分:统计质量控制术语GB/T 3358. 3-1993统计学术语第三部分:试验设计术语GB/T 6379. 2-2004测量方法与结果的准确度(正确度和精密度)第2部分:确定标准测量方法的重复性和再现性的基本方法ISO 3534-1:1993统计学词汇和符号第1部分:概率和一般统计术语ISO 5725-3:1994测量方法与结果的准确度(正确度和精密度)第3部分标准测量方法精密度的中间度量ISO 5725-4:1994测量方法与结果的准确度(正确度和精密度)第4部分:确定标准测量方法的正确度的基本方法3定义下列定义适用于GB/T 6379的本部分,其中部分定义引自ISO 3534GB/T 6379使用的符号由附录A给出。www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:1994观测值(observed value)作为一次观测结果而确定的特性值。(引自GB/T 3358. 1-1993)3.2测试结果(test result)用规定的测试方法所确定的特性值。(改自GB/T 3358. 1-1993 )注1;测试方法宜指明观测是一个还是多个,报告的测试结果是观测值的平均数还是它的其他函数(例如中位数或标准差).它可以要求按适用的标准进行修正,如气体容积按标准温度和压力进行修正.因此一个测试结果可以是通过几个观测值计算的结果。在最简单情形,测试结果即为观测值本身.3.3精密度试验的测试水平(level of the test in a precision experiment)对某测试物料或试样,所有实验室测试结果的总平均值。3.4精密度实验单元(cell in a precision experiment)由一个实验室在单一水平获得的测试结果3.5接受参照值(accepted reference value)用作比较的经协商同意的标准值,它来自于:a)基于科学原理的理论值或确定值;b)基于一些国家或国际组织的实验工作的指定值或认证值;c)基于科学或工程组织赞助下合作实验工作中的同意值或认证值;d)当a) b) c)不能获得时,则用(可测)量的期望,即规定测量总体的均值。3.6准确度(accuracy)测试结果与接受参照值间的一致程度。(改自GB/T 3358. 1-1993 )注2:术语准确度,当用于一组测试结果时,由随机误差分量和系统误差即偏倚分量组成。3.71E确度(trueness)由大量测试结果得到的平均数与接受参照值间的一致程度。注3:正确度的度量通常用术语偏倚表示注4:准确度曾被称为“平均数的准确度”,这种用法不被推荐。3.8偏倚(bias)测试结果的期望与接受参照值之差。注5:与随机误差相反,偏倚是系统误差的总和。偏倚可能由一个或多个系统误差引起。系统误差与接受参照值之差越大,偏倚就越大。3. 9实验室偏倚(laboratory bias)一个特定的实验室的测试结果的期望与接受参照值之差。www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:19943. 10测f方法偏倚(bias of the measurement method)所有采用该方法的实验室所得测试结果的期望与接受参照值之差。注6:实际操作中的例。如测量某化合物中硫的含量,由于测量方法不可能提尽所有的硫,因此该测量方法将有一个负的偏倚。对很多使用相同的方法的不同的实验室得到的测试结果求平均值,就可用来测定该测量方法的偏倚测量方法的偏倚在不同水平下可以是不同的。3. 11偏倚的实验室分f (laboratory component of bias)实验室偏倚与测量方法偏倚之差。注7:偏倚的实验室分量是针对特定实验室和实验室所具有的测量条件的,在不同的测试水平下也可以是不同的。注8:偏倚的实验室分量与测试结果的总平均值有关,而与真值或标准值无关。3. 12精密度(precision)在规定条件下,独立测试结果间的一致程度。(改自GB/T 3358. 1-1993 )注9精密度仅仅依赖于随机误差的分布而与真值或规定值无关。注加:精密度的度量通常以不精密度表达,其量值用测试结果的标准差来表示,精密度越低,标准差越大。注n:“独立测试结果”指的是对相同或相似的测试对象所得的结果不受以前任何结果的影响。精密度的定量的测度严格依赖于规定的条件,重复性和再现性条件为其中两种极端情况。3. 13重复性(repeatability)在重复性条件下的精密度。(改自GB/T 3358.1-1993 )3. 14重复性条件(repeatability conditions)在同一实验室,由同一操作员使用相同的设备,按相同的测试方法,在短时间内对同一被测对象相互独立进行的测试条件。(引自GB/T 3358. 1-1993)3.15重复性标准差(repeatability standard deviation)在重复性条件下所得测试结果的标准差(引自GB/T 3358. 1-1993)注12:重复性标准差是重复性条件下测试结果分布的分散性的度量。注13:类似地可定义“重复性方差”与“重复性变异系数”,作为重复性条件下测试结果分散性的度量3. 16重复性限(repeatability limit)一个数值,在重复性条件下,两个测试结果的绝对差小于或等于此数的概率为95环。(引自GB/T 3358. 1-1993)注14:重复性限用;来表示3. 17再现性(reproducibility)在再现性条件下的精密度。(改自GB/T 3358. 1-1993)3www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:19943.18再现性条件(reproducibility conditions)在不同的实验室,由不同的操作员使用不同设备,按相同的测试方法,对同一被测对象相互独立进行的测试条件(改自GB/T 3358. 1-1993)3. 19再现性标准差(reproducibility standard deviation)在再现性条件下所得测试结果的标准差。(引自GB/T 3358. 1-1993)注15:再现性标准差是再现性条件下测试结果分布的分散性的度量注16类似地可定义“再现性方差”与“再现性变异系数”,作为再现性条件下测试结果分散性的度量。3.20再现性限(reproducibility limit)一个数值,在再现性条件下,两个测试结果的绝对差小于或等于此数的概率为95%.(引自GB/T 3358. 1-1993)注17:再现性限用符号R表示3.21离群值(outlier)样本中的一个或几个观测值,它们离开其他观测值较远,暗示它们可能来自不同的总体。(引自GB/T 3358. 1-1993)注18;GB/T 6379.2规定了在正确度和精密度试验中,用来识别离群值的统计检验和显著性水平3.22协同评定试验(collaborative assessment experiment)一种实验室间的试验,在这样的试验中,用相同的标准测量方法对同一物料进行测试,以评定每个实验室的水准。注19在3.16和3. 20中给出的定义适用于观测值为连续变化的情形如果测试结果是离散的或经过修约的,那么前面所定义的重复性限和再现性限是各自满足以下条件值的最小值;两个测试结果差的绝对值小于或等于该值的概率不小于95注20:由3.8到3.11,3. 15,3. 16,3.19和3. 20中所给的定义的诸量,指的都是实际中未知的理论值实际确定重复性和再现性标准差及偏倚时用GB/T 6379.2和ISO 5725-4中所描述的试验,用统计语言说是这些理论值的估计值,因此会有误差。例如,与r和R相关的概率水平将不会正好等于95%。当很多实验室参与一个精密度试验时,这些概率水平将近似等于95 %,但是当参与精密度实验的实验室数目少于3。时,概率水平可能偏离95%较远。这是不可避免的,但是也不要过于低估它们的实际效用,因为设计它们的原意就是要作为一种工具,用来判断实验结果之间的差别是否是由于测量方法的随机不确定因素造成的.比重复性限r和再现性限R大的差值应该引起关注注21;符号犷和R在其他地方有其它更一般的含义;例如在ISO 3534-1中r表示相关系数,R(或W)表示一组观测值的极差。如果有可能产生误解,特别是在标准中引用时,宜使用全称重复性限r或再现性限R,这样就不致引起混淆。4准确度试验定义的实际含义a. 1标准测f方法4.1.1为使测量按同样的方法进行,测量方法应标准化。所有测量都应该根据规定的标准方法进行。这意味着必须要有一个书面的文件,规定有关如何进行测量的所有的细节,最好还要包括如何获得和准备试样的内容。www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:19944.1.2有关测量方法文件的存在意味着有一个负责研究测量方法机构的存在。注22:在6. 2中将更全面的讨论标准测量方法.4.2准确度试验4.2. 1准确度(正确度和精密度)的度量宜由参加试验的实验室报告的系列测试结果确定。由为此目的而专门设立的专家组组织所有测试这样一个不同实验室间的试验称为“准确度试验”。准确度试验根据其限定目标也可称为“精密度试验”或“正确度试验”。如果目标是确定正确度,那么应事先或同时进行精密度试验通过这样试验得到的准确度的估计值,宜指明所用的标准测量方法,且结果仅在所用的方法下才有效。4.2.2准确度试验通常可以认为是一次标准测量方法是否适合的一个实际测试。标准化的主要目标之一就是要尽可能的估计用户(实验室)之间的差异,由准确度试验提供的数据将会揭示出这个目标是如何有效取得的。实验室内方差(见第7章)或实验室均值之间的差异可能表明标准测量方法还不够详细,可以进一步改进。如果这样,宜将问题报告给标准化团体以便进一步调查。4.3同一测试对象4.3.,在一个准确度试验中,规定物料或规定产品的样本从一个中心点发往位于不同地点,不同国家,甚至不同洲的许多实验室。重复性条件的定义((3. 14)指出在这些实验室中进行的测量应该对同一测试对象,并在实际同一时段内进行。为此应满足以下两个不同的条件:a)分送各实验室的样本应该是相同的;b)样本在运输过程和在实际测试前所耗费的时间须保持相同在组织精确度试验中,要仔细考察这两个条件是否得到满足注23:在6. 4中将更全面讨论物料的选取。4.4短暂的时间间隔4.4. 1根据重复性条件的定义((3.14),确定重复性的测量必须在恒定的操作条件下进行;即在整个测量时间段内,在0. 3中所列的那些因素必须保持不变。特别,设备在两次测量之间不应重新校准,除非校准是单个测量中一个基本的组成部分在实际中,在重复性条件下进行的试验宜在尽可能短的时间间隔内进行以便使那些不能总是保证不变的因素,比如环境因素的变化最小。4.4.2影响不同观测之间的时间间隔的另一因素是测试结果的独立性假定。为避免前面的测试结果可能会影响以下的测试结果(从而可能低估重复性方差),就有必要按以下方式提供样本:操作员根据样品编号不知道哪些样品是相同的指示操作员按一定观测顺序操作,而顺序是随机的,以使所有的“同一”测试对象的测试不会一起进行。这也许意味着违背了重复测量应在一个短的时间段内完成的初衷,除非全部测量能在一个很短的时间间隔内完成。4.5参与的实验室4.5.1 GB/T6379的本部分的一个基本假定是对一个标准测量方法而言,重复性对使用这个标准程序的每个实验室应该或至少是近似相同的,这样可以允许建立一个共同的平均重复性标准差,它适用于任何实验室。然而,每个实验室在重复性条件下进行一系列观测时,都能就该测量方法得到一个自己的重复性标准差的估计值,并可据此与共同的标准差的值来校核该估计值。ISO 5725-6详细地讨论了这种方法。4.5.2在3.8到3. 20中定义的量,理论上适用于可能使用所述测量方法的所有实验室。但在实际上,它们是根据这个实验室总体的一个样本来确定的。选择这个样本的进一步细节将在6.3中讨论。当参加试验的实验室数及测量数都达到6.3中规定的数量时,所获得的正确度与精密度的估计值即可满足要求。然而,如果将来某一时间,有证据表明参加测试的实验室不能或不再能真正代表所有使用该标准测量方法的实验室,那么测量就将重新进行。4.6观测条件4.6. 1在0. 3中列出了能使在一个实验室内获得的观测值产生变异的所有因素。这些因素包括时间、5www.bzfxw.comGB/T 6379.1-2004/ISO 5725-1:1994操作员与设备等。因为在不同时间进行测试时,由于环境条件的改变及设备的重新校准等都会使观测值受到影响。在重复性条件下,观测值是在所有这些因素不变的情况下取得的;在再现性条件下,观测值是在不同的实验室获得的,由于实验室的不同,不仅所有其他因素会发生改变,而且由于在两个实验室之间的管理和维护以及观测值的稳定性检查等诸多方面的差异也会对结果产生不同的影响。4.6.2有时也有必要考虑中间精密度条件,即观测值是在相同的实验室获得,但是允许时间、操作员或设备中的一个或几个因素发生改变。在确定测量方法的精密度时,很重要的一点就是要规定观测条件,即上述时间、操作员和设备这三个因素哪些不变,哪些改变。此外,这三个因素所引起的差异的数值大小也与测量方法有关。例如,在化学分析中,“操作员”和“时间”是主要因素;微量分析中,“设备”和“环境”是主要因素;而在物理测试中,“设备”和“校准”是主要因素。5统计模型5.1基本模型为估计测量方法的准确度(正确度和精密度),假定对给定的受试物料,每个测试结果Y是三个分量的和:Y二m+B+e·················,······……(1)式中:m—总平均值(期望);B—重复性条件下偏倚的实验室分量;。—重复性条件下每次测量产生的随机误差。5.1.1总平均值m5.1.1.1总平均值m是测试水平;一种化学品或物料的不同成分的样品(例如不同类型的钢材)对应着不同的水平。在很多技术场合,测试水平仅由测量方法确定,独立真值的概念并不适用。然而,在某些情况下,受试特性的真值k的概念仍可使用,例如一种正在滴定溶液的真正浓度。总平均值m未必与真值产相等。5. 1. 1.2在检查用相同测量方法获得的测试结果间的差异时,测量方法的偏倚不会对其产生影响,因此可以忽略。然而,当把测试结果和一个在合同中或标准中规定的值进行比较时,其中合同或标准中指的是真值du而不是测试水平m,或者比较不同的测量方法得到的结果时,必须考虑测量方法的偏倚。如果存在一个真值,并且可以获得满意的参照物,那么就应该用ISO 5725-4中的方法确定测量方法的偏倚。5. 1.2分f B5. 1.2. 1在重复性条件下进行的任何系列测试中,分量B可以认为是常数,但是在其他条件下进行的测试,分量B则会不同。当只对两个相同的实验室比较测试结果时,有必要确定它们相应的偏倚,通过准确度实验测定各自的偏倚,或通过在它们之间专门的试验确定。然而,若对不特别指定的两个实验室之间差异进行一般性的描述,或者对两个还没有确定其各自偏倚的实验室进行比较时,必须考虑偏倚的实验室分量的分布,这就是引进再现性概念的理由。在GB/T 6379. 2中给出的程序,是在假定偏倚的实验室分量是近似正态分布情况下得到的,但在多数实际情形只须假定分布为单峰的即可。5. 1. 2. 2 B的方差称为实验室间方差,用下式表示:var(B)=。免······························……(2)其中。盖包含操作员间和设备间的变异。在GB/T 6379. 2中描述的基本精密度试验中,这些分量没有被分拆。在ISO 5725-3中给出了测量B的某些随机分量的大小的方法5. 1.2.3通常,B可以看作为是随机分量和系统分量之和。这里并不试图列出所有与B有关的因素,6www.bzfxw.com